What a portable air conditioner costs to run: the label's maths, and a calculator
The yearly kWh on a portable air conditioner's energy label is rated power multiplied by a fixed number of hours for your climate zone. Here is the sum, and a calculator.
The energy label on a portable air conditioner shows zero stars, so the useful number on it is the yearly energy use in kWh. For the usual single-duct design, that number turns out to be very simple.
The sum behind the label
The label gives a figure for each of three climate zones. For single-duct portables it is the unit's rated power multiplied by a fixed number of hours:
- Cold zone (Melbourne, Canberra, Hobart): 545 hours a year
- Average zone (Sydney, Perth, Adelaide): 840 hours a year
- Hot zone (Brisbane, Darwin): 2,247 hours a year
We worked those hours out from the register itself, by dividing each model's registered yearly kWh by its rated power. Every one of the 395 fixed-speed portable models in the register gives the same three answers.
So a unit rated at 1,000 W is labelled at 840 kWh a year for Sydney and 2,247 kWh a year for Brisbane. Multiply by what you pay per kWh and you have the label's idea of your yearly cost.
| Rated power | Cold zone (545 h) | Average zone (840 h) | Hot zone (2,247 h) |
|---|---|---|---|
| 750 W | 409 kWh · $143 | 630 kWh · $220 | 1,685 kWh · $590 |
| 1,000 W | 545 kWh · $191 | 840 kWh · $294 | 2,247 kWh · $786 |
| 1,300 W | 708 kWh · $248 | 1,092 kWh · $382 | 2,921 kWh · $1,022 |
| 1,700 W | 926 kWh · $324 | 1,428 kWh · $500 | 3,820 kWh · $1,337 |
The dollar figures use 35 cents per kWh purely as an example. Your rate is on your electricity bill.
Work out your own
The label's hours are a standard assumption. Your summer is yours. Put in your own numbers:
The calculator needs JavaScript. Without it, the sum is: watts × hours × days ÷ 1,000 × price per kWh.
What this leaves out
- Rated power is the draw at full cooling. When the thermostat is satisfied, a fixed-speed compressor switches off and an inverter slows down. Real use is lower than the full-power sum, sometimes much lower in a small, shaded room.
- A unit that is too small never rests. It runs flat out and still does not get the room to temperature, so it uses its full rated power for every hour it is on.
- Fan-only and standby power are not counted here. They are small by comparison.
Where efficiency fits in
Rated power on its own does not tell you whether a unit is good value to run, because a bigger unit draws more and cools more. The fair comparison is cooling per watt, which is the EER. Two units that both deliver 3.5 kW of cooling can differ by several hundred watts. See the most efficient models.