The yearly kWh on a portable air conditioner's energy label is rated power multiplied by a fixed number of hours for your climate zone. Here is the sum, and a calculator.

Updated 23 November 2026 · Register data as at 23 November 2026 · How we got these numbers

The energy label on a portable air conditioner shows zero stars, so the useful number on it is the yearly energy use in kWh. For the usual single-duct design, that number turns out to be very simple.

The sum behind the label

The label gives a figure for each of three climate zones. For single-duct portables it is the unit's rated power multiplied by a fixed number of hours:

We worked those hours out from the register itself, by dividing each model's registered yearly kWh by its rated power. Every one of the 395 fixed-speed portable models in the register gives the same three answers.

So a unit rated at 1,000 W is labelled at 840 kWh a year for Sydney and 2,247 kWh a year for Brisbane. Multiply by what you pay per kWh and you have the label's idea of your yearly cost.

Label-style yearly energy use, with cost at an example 35 c/kWh
Rated powerCold zone (545 h)Average zone (840 h)Hot zone (2,247 h)
750 W409 kWh · $143630 kWh · $2201,685 kWh · $590
1,000 W545 kWh · $191840 kWh · $2942,247 kWh · $786
1,300 W708 kWh · $2481,092 kWh · $3822,921 kWh · $1,022
1,700 W926 kWh · $3241,428 kWh · $5003,820 kWh · $1,337

The dollar figures use 35 cents per kWh purely as an example. Your rate is on your electricity bill.

Work out your own

The label's hours are a standard assumption. Your summer is yours. Put in your own numbers:

The calculator needs JavaScript. Without it, the sum is: watts × hours × days ÷ 1,000 × price per kWh.

What this leaves out

Where efficiency fits in

Rated power on its own does not tell you whether a unit is good value to run, because a bigger unit draws more and cools more. The fair comparison is cooling per watt, which is the EER. Two units that both deliver 3.5 kW of cooling can differ by several hundred watts. See the most efficient models.