The most efficient portable air conditioners in Australia, by registered EER
Most portable air conditioners sit just above the legal minimum efficiency of 2.50. These are the 13 registrations at 2.95 or better, and what the gap is worth.
Noise barely separates one portable air conditioner from the next. Efficiency does. The figure to look at is the EER: cooling output divided by electrical power input. An EER of 3.0 means 3 kW of cooling for every 1 kW of electricity.
Most models only just clear the legal minimum
Australian rules set a minimum EER of 2.50 for portable air conditioners. Of the 321 models registered for sale since 23 November 2022, 273 (85%) are registered between 2.5 and 2.8. The median is 2.63. Only 21 models reach 3.0 or more, and the best is 3.64.
The top of the list
| Brand and model | EER | Cooling kW | Power W | Noise dB(A) | Type | Registered |
|---|---|---|---|---|---|---|
| Westinghouse WPV097CR1WA | 3.64 | 2.6 | 720 | 63.5 | inverter | Jun 2026 |
| TCL TAC-12CHPB/NUBp, TAC-12CHPB/NVBp, TAC-12CHPB/NWBp +3 more | 3.61 | 3.5 | 975 | 63.87 | inverter, heats too | Apr 2024 |
| TCL TAC-12CPB/NUBp, TAC-12CPB/NVBp, TAC-12CPB/NWBp +3 more | 3.6 | 3.5 | 975 | 63.74 | inverter | Apr 2024 |
| De'Longhi PAC AP130i | 3.27 | 3.3 | 1035 | 63.6 | inverter | Mar 2026 |
| Westinghouse WPV127CR1WA | 3.16 | 3.4 | 1100 | 63.5 | inverter | Jun 2026 |
| Ausclimate ACPAC355 | 3.14 | 3.54 | 1130 | 63.7 | – | Oct 2024 |
| Solt GGSAP2900B, GGSAP2900S, GGSAP2900W | 3.12 | 3 | 950 | 61.3 | – | Jun 2025 |
| Midea MPPD30C | 3.12 | 3 | 950 | 61.3 | – | Jul 2026 |
| Zero Breeze Z30 | 3.11 | 1.54 | 490 | 51.3 | inverter, double duct, heats too | Aug 2026 |
| De'Longhi PAC AP140i | 2.98 | 3.7 | 1280 | 64.5 | inverter | Mar 2026 |
| De'Longhi PAC EL112 CST WIFI | 2.97 | 2.9 | 950 | 62.9 | – | Feb 2023 |
| Kogan KASIPAC14YA, KASIPAC14YB, KASIPAC14YC +1 more | 2.97 | 4.1 | 1390 | 63.5 | inverter | Sep 2024 |
| Hyundai HY07KSPACPA, HY07KSPACPB, HY07KSPACPC +1 more | 2.95 | 2 | 769 | 64.2 | – | May 2025 |
Power is the rated electrical input in watts at full cooling. Noise is registered sound power in dB(A). Several entries cover a family of colour or trim variants with the same figures.
What the gap is worth
Take a unit rated at 3.5 kW of cooling. At the median EER of 2.63 it draws about 1,331 W. At an EER of 3.6 it draws about 972 W for the same cooling. Over the 840 hours a year that the energy label assumes for Sydney, Perth and Adelaide, that is roughly 301 kWh, or about $105 a year at 35 cents per kWh. In Brisbane or Darwin, where the label assumes 2,247 hours, the gap is about 2.7 times that.
Use your own tariff and your own hours in the running cost calculator.
Why you cannot use the star rating
Single-duct portable air conditioners are required to show zero stars on the energy label in every climate zone. That is 319 of the 321 models here. The Energy Rating program's explanation is that single-duct portables are the least efficient type of air conditioner the rules cover: they blow room air outside through the hose, and warmer air is drawn in to replace it. So the label cannot rank them for you. The EER and the yearly kWh figure can. More on single and double duct.
What EER does not cover
- It is measured at one set of test conditions. Real efficiency moves with the weather and with how the hose and window kit are fitted.
- It does not count the warm air a single-duct unit pulls into the room. Every single-duct model shares that weakness, so EER still ranks them fairly against each other. It flatters all of them against a split system.
- It says nothing about reliability, noise or after-sales support.
Bottom line. If two models suit your room, the one with the higher EER costs less to run for the same cooling, every hour it is on. Above about 3.0 you are in the top handful of the market.