Fewest Regrets

Portable air conditioners

Inverter portable air conditioners: which models, and are they better?

23 of 321 portable air conditioners in the register have a variable-speed compressor. They are more efficient on average, and no quieter at full power.

Updated 23 November 2026 · Register data as at 23 November 2026 · How we got these numbers

An inverter (variable-speed) compressor can slow down instead of switching fully on and off. In split systems it is now the norm. In portable air conditioners it is still rare: 23 of the 321 models registered for sale in Australia since 23 November 2022 are variable speed, across 10 registrations.

The inverter models

Variable-speed (inverter) portable air conditioners in the register
Brand and modelEERCooling kWPower WNoise dB(A)OtherRegistered
Westinghouse WPV097CR1WA3.642.672063.5–Jun 2026
TCL TAC-12CHPB/NUBp, TAC-12CHPB/NVBp, TAC-12CHPB/NWBp +3 more3.613.597563.87heats tooApr 2024
TCL TAC-12CPB/NUBp, TAC-12CPB/NVBp, TAC-12CPB/NWBp +3 more3.63.597563.74–Apr 2024
De'Longhi PAC AP130i3.273.3103563.6–Mar 2026
Westinghouse WPV127CR1WA3.163.4110063.5–Jun 2026
Zero Breeze Z303.111.5449051.3double duct, heats tooAug 2026
De'Longhi PAC AP140i2.983.7128064.5–Mar 2026
Kogan KASIPAC14YA, KASIPAC14YB, KASIPAC14YC +1 more2.974.1139063.5–Sep 2024
Zero Breeze Z202.840.6322046.3double ductSep 2026
EcoFlow EFKT2102.621.555064.7heats tooMar 2023

Are they more efficient?

On average, yes. Counting each registration once, the median registered EER of the inverter units is 3.13, against 2.63 for fixed-speed units. 6 of the 10 inverter registrations are at 3.0 or better. Among the 167 fixed-speed registrations, 3 are.

But "inverter" on the box does not guarantee it. The lowest registered EER among the inverter units is 2.62, no better than an ordinary one. And the best fixed-speed unit is registered at 3.14, ahead of several of the inverters. Check the EER of the specific model.

Are they quieter?

Not in any way you would hear at full power. The median registered noise of the full-size inverter units is 63.7 dB(A). For fixed-speed units it is 64. (The two very small Zero Breeze units are much quieter, but they are a different class of machine.)

The register only records noise at full cooling, which is exactly where an inverter has no advantage. Where it can help is afterwards: once the room is cool, a variable-speed compressor can keep running slowly and steadily instead of stopping and restarting. Many people find that less intrusive than the on-off cycle of a fixed-speed unit, especially at night. The register has no figure for that, so look for a review that measured it.

When an inverter is worth paying for

If you only need a few hours of cooling on the worst days of summer, the extra purchase price is hard to recover.